Enthalpy (T)
Measurement details
Measured with | TA Q200 |
By: | Fraunhofer ISE |
Additional Comments | Variation of heating rates from 4 K/min to 0.25 K/min (4, 2, 1, 0.5, 0.25 K/min), starting with cooling (4K/min). Determination of heating rate is not possible due to appearance of several peaks. |
- Heating rate: 1.0 [K/min]
- Cooling rate: 1.0 [K/min]
- Sample mass: 9.21 [mg]
- Heat of fusion: 135.9 [kJ/kg] - deviation: 0.3 [kJ/kg]
- Integration range, lower limit: -5.0 [°C]
- Integration range, upper limit: 30.0 [°C]
- Onset temperature: 12.7 [°C] - deviation: [°C]
- Offset temperature: 22.8 [°C] - deviation: [°C]
- Crystallization enthalpy: 133.5 [kJ/kg] -
deviation: 0.8 [kJ/kg]
- Integration range, lower limit: -10.0 [°C]
- Integration range, upper limit: 20.0 [°C]
- Onset: 17.4 [°C] - deviation: [°C]
- Offset: 10.0 [°C] - deviation: [°C]