You are here: Home / PCM / Octadecan Parafol 18-97 / Enthalpy (T)

Enthalpy (T)

Measurement details

Measured with TA Q200 (Heatflux)
By: Fraunhofer ISE
Additional Comments Sample 3
  • Heating rate0.5 [K/min]
  • Cooling rate0.5 [K/min]
  • Sample mass8.79 [mg]
  • Heat of fusion231.2 [kJ/kg] - deviation0.2 [kJ/kg]
    • Integration range, lower limit20.0 [°C]
    • Integration range, upper limit34.0 [°C]
    • Onset temperature27.39 [°C] - deviation0.02 [°C]
    • Offset temperature29.44 [°C] - deviation0.05 [°C]
  • Crystallization enthalpy232.7 [kJ/kg] - deviation0.2 [kJ/kg]
    • Integration range, lower limit20.0 [°C]
    • Integration range, upper limit27.0 [°C]
    • Onset26.51 [°C] - deviation0.02 [°C]
    • Offset26.45 [°C] - deviation0.39 [°C]

Set 1/ db-materials-heating_cooling_measurements

Heating - sample3_melt_cycle1_0K5.dat

Cooling - sample3_cool_cycle1_0K5.dat

Set 2/ db-materials-heating_cooling_measurements-1

Heating - sample3_melt_cycle2_0K5.dat

Cooling - sample3_cool_cycle2_0K5.dat

Set 3/ db-materials-heating_cooling_measurements-2

Heating - sample3_melt_cycle3_0K5.dat

Cooling - sample3_cool_cycle3_0K5.dat