Enthalpy (T)
Measurement details
Measured with | TA DSC2500 |
By: | Fraunhofer ISE |
Additional Comments | The crucible has a hole in the lid. The sample (with crucible) was previously measured in a TGA to determine the dry mass. The sample was sufficiently dry. |
- Heating rate: 0.5 [K/min]
- Cooling rate: 0.5 [K/min]
- Sample mass: 10.6 [mg]
- Heat of fusion: 175.6 [kJ/kg] - deviation: 0.4 [kJ/kg]
- Integration range, lower limit: 295.0 [°C]
- Integration range, upper limit: 310.0 [°C]
- Onset temperature: 306.93 [°C] - deviation: 0.16 [°C]
- Offset temperature: [°C] - deviation: [°C]
- Crystallization enthalpy: 176.4 [kJ/kg] -
deviation: 0.2 [kJ/kg]
- Integration range, lower limit: 295.0 [°C]
- Integration range, upper limit: 303.0 [°C]
- Onset: 300.5 [°C] - deviation: 2.0 [°C]
- Offset: [°C] - deviation: [°C]