Enthalpy (T)
Measurement details
Measured with | TA Q2000 |
By: | ZAE Bayern |
Additional Comments | sample 3 of 3, subtraction of blank crucible was not necessary (signal of blank measurement negligible) |
- Heating rate: 1.0 [K/min]
- Cooling rate: 1.0 [K/min]
- Sample mass: 7.689 [mg]
- Heat of fusion: 180.6 [kJ/kg] - deviation: 0.2 [kJ/kg]
- Integration range, lower limit: 40.0 [°C]
- Integration range, upper limit: 50.0 [°C]
- Onset temperature: 43.4 [°C] - deviation: 0.0 [°C]
- Offset temperature: 45.9 [°C] - deviation: 0.2 [°C]
- Crystallization enthalpy: 185.4 [kJ/kg] -
deviation: 0.2 [kJ/kg]
- Integration range, lower limit: 33.0 [°C]
- Integration range, upper limit: 43.0 [°C]
- Onset: 40.0 [°C] - deviation: 0.2 [°C]
- Offset: 39.2 [°C] - deviation: 0.3 [°C]