You are here: Home / PCM / Micronal DS 5040 X / Enthalpy (T)

Enthalpy (T)

Measurement details

Measured with Setaram MicroDSCIII
By: Fraunhofer ISE
Additional Comments
  • Heating rate0.05 [K/min]
  • Cooling rate0.05 [K/min]
  • Sample mass217.95 [mg]
  • Heat of fusion93.52 [kJ/kg] - deviation0.1 [kJ/kg]
    • Integration range, lower limit10.0 [°C]
    • Integration range, upper limit26.0 [°C]
    • Onset temperature19.07 [°C] - deviation [°C]
    • Offset temperature25.26 [°C] - deviation [°C]
  • Crystallization enthalpy92.98 [kJ/kg] - deviation0.03 [kJ/kg]
    • Integration range, lower limit10.0 [°C]
    • Integration range, upper limit25.0 [°C]
    • Onset23.94 [°C] - deviation [°C]
    • Offset25.26 [°C] - deviation [°C]
Enthalpy (T)

Set 1/ db-materials-heating_cooling_measurements

Heating - Fraunhofer_ISE_Micronal_DS_5040_X_Sample3_Cycle1_0K05_min_Heating.dat

Cooling - Fraunhofer_ISE_Micronal_DS_5040_X_Sample3_Cycle1_0K05_min_Cooling.dat