Enthalpy (T)
Measurement details
Measured with | TA Q2000 |
By: | ZAE Bayern |
Additional Comments | Sample 2 of 3. Integration range for crystallization enthalpy was 0 to 5 °C for cycles 1 and 2, and 5 to 10 °C for cycle 3. |
- Heating rate: 0.5 [K/min]
- Cooling rate: 0.5 [K/min]
- Sample mass: 12.785 [mg]
- Heat of fusion: 134.4 [kJ/kg] - deviation: 0.2 [kJ/kg]
- Integration range, lower limit: 25.0 [°C]
- Integration range, upper limit: 40.0 [°C]
- Onset temperature: 33.3 [°C] - deviation: 0.1 [°C]
- Offset temperature: 35.3 [°C] - deviation: 0.1 [°C]
- Crystallization enthalpy: 112.0 [kJ/kg] -
deviation: 3.6 [kJ/kg]
- Integration range, lower limit: 0.0 [°C]
- Integration range, upper limit: 5.0 [°C]
- Onset: 3.7 [°C] - deviation: 4.0 [°C]
- Offset: 3.3 [°C] - deviation: 4.0 [°C]