- Info
Enthalpy (T)
Measurement details
Measured with |
TA Q2000 |
By:
|
ZAE Bayern |
Additional Comments |
Sample 1 of 3. |
- Heating rate: 0.5 [K/min]
- Cooling rate: 0.5 [K/min]
- Sample mass: 11.225 [mg]
- Heat of fusion: 136.8 [kJ/kg] - deviation: 0.1 [kJ/kg]
- Integration range, lower limit: 25.0 [°C]
- Integration range, upper limit: 40.0 [°C]
- Onset temperature: 33.2 [°C] -
deviation: 0.0 [°C]
- Offset temperature: 35.3 [°C] -
deviation: 0.0 [°C]
- Crystallization enthalpy: 118.0 [kJ/kg] -
deviation: 1.9 [kJ/kg]
- Integration range, lower limit: 0.0 [°C]
- Integration range, upper limit: 5.0 [°C]
- Onset: 1.5 [°C] -
deviation: 1.3 [°C]
- Offset: 1.0 [°C] -
deviation: 1.3 [°C]
Set 1/ db-materials-heating_cooling_measurements
Set 2/ db-materials-heating_cooling_measurements-1
Set 3/ db-materials-heating_cooling_measurements-2