enthalpy sample 1

Measured by
Austrian Institute of Technology
Measured with NETZSCH DSC 204 F1 Phoenix
Measured according to standard
None
Comment on measurement
Crucible: Al. pan, closed. Purge gas: Nitrogen with 20 ml/min. 3 Heating & Cooling cycles between 140 and 220 °C with 10 K/min. Heat calibration performed.
Reference
Heating rate
10 K/min
Cooling rate
10 K/min
Sample mass
11.06 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
328.13 kJ/kg
7.46 kJ/kg
293.97 kJ/kg
6.89 kJ/kg
Integration lower limit
174.07 °C
173.2 °C
Integration upper limit
216.3 °C
145.6 °C
Onset temperature
186.17 °C
0.29 K
171.5 °C
0 K
Endset temperature
200.57 °C
0.35 K
159.57 °C
0.07 K
Succinic acid: Heating/cooling enthalpy measurement 1
Succinic acid: Heating/cooling enthalpy measurement 2
Succinic acid: Heating/cooling enthalpy measurement 3

Succinic acid: Heating/cooling enthalpy measurement 1

Succinic acid: Heating/cooling enthalpy measurement 1

Succinic acid: Heating/cooling enthalpy measurement 2

Succinic acid: Heating/cooling enthalpy measurement 2

Succinic acid: Heating/cooling enthalpy measurement 3

Succinic acid: Heating/cooling enthalpy measurement 3