enthalpy sample 3

Measured by
Austrian Institute of Technology
Measured with NETZSCH DSC 204 F1 Phoenix
Measured according to standard
None
Comment on measurement
Crucible: Al. pan, closed. Purge gas: Nitrogen with 20 ml/min. 3 Heating & Cooling cycles between 105 and 160 °C with 10 K/min. Heat calibration performed.
Reference
Heating rate
10 K/min
Cooling rate
10 K/min
Sample mass
9.28 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
242.73 kJ/kg
2.47 kJ/kg
245.1 kJ/kg
0.61 kJ/kg
Integration lower limit
124.34 °C
111.64 °C
Integration upper limit
154.09 °C
138.52 °C
Onset temperature
132.17 °C
0.07 K
137.13 °C
0.24 K
Endset temperature
147.77 °C
0.18 K
117.63 °C
0.77 K
Suberic acid: Heating/cooling enthalpy measurement 1
Suberic acid: Heating/cooling enthalpy measurement 2
Suberic acid: Heating/cooling enthalpy measurement 3

Suberic acid: Heating/cooling enthalpy measurement 1

Suberic acid: Heating/cooling enthalpy measurement 1

Suberic acid: Heating/cooling enthalpy measurement 2

Suberic acid: Heating/cooling enthalpy measurement 2

Suberic acid: Heating/cooling enthalpy measurement 3

Suberic acid: Heating/cooling enthalpy measurement 3