| Measured by | Austrian Institute of Technology | |||
|---|---|---|---|---|
| Measured with | NETZSCH DSC 204 F1 Phoenix | |||
| Measured according to standard | None | |||
| Comment on measurement | Crucible: Al. pan, closed. Purge gas: Nitrogen with 20 ml/min. 3 Heating & Cooling cycles between 105 and 160 °C with 10 K/min. Heat calibration performed. | |||
| Reference | ||||
| Heating rate | 10 K/min | |||
| Cooling rate | 10 K/min | |||
| Sample mass | 9.28 mg | |||
| Endothermic heat flow | Exothermic heat flow | |||
| Value | Uncertainty | Value | Uncertainty | |
| Enthalpy | 242.73 kJ/kg | 2.47 kJ/kg | 245.1 kJ/kg | 0.61 kJ/kg |
| Integration lower limit | 124.34 °C | 111.64 °C | ||
| Integration upper limit | 154.09 °C | 138.52 °C | ||
| Onset temperature | 132.17 °C | 0.07 K | 137.13 °C | 0.24 K |
| Endset temperature | 147.77 °C | 0.18 K | 117.63 °C | 0.77 K |