enthalpy sample 2

Measured by
Austrian Institute of Technology
Measured with NETZSCH DSC 204 F1 Phoenix
Measured according to standard
None
Comment on measurement
Crucible: Al. pan, closed. Purge gas: Nitrogen with 20 ml/min. 3 Heating & Cooling cycles between 105 and 160 °C with 10 K/min. Heat calibration performed.
Reference
Heating rate
10 K/min
Cooling rate
10 K/min
Sample mass
8.36 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
240.3 kJ/kg
2.62 kJ/kg
244.43 kJ/kg
1.01 kJ/kg
Integration lower limit
124.45 °C
138.36 °C
Integration upper limit
152.92 °C
109.97 °C
Onset temperature
132.03 °C
0.07 K
136.83 °C
0.18 K
Endset temperature
147.03 °C
0.18 K
120.3 °C
2.91 K
Suberic acid: Heating/cooling enthalpy measurement 1
Suberic acid: Heating/cooling enthalpy measurement 2
Suberic acid: Heating/cooling enthalpy measurement 3

Suberic acid: Heating/cooling enthalpy measurement 1

Suberic acid: Heating/cooling enthalpy measurement 1

Suberic acid: Heating/cooling enthalpy measurement 2

Suberic acid: Heating/cooling enthalpy measurement 2

Suberic acid: Heating/cooling enthalpy measurement 3

Suberic acid: Heating/cooling enthalpy measurement 3