enthalpy sample 1

Measured by
Austrian Institute of Technology
Measured with NETZSCH DSC 204 F1 Phoenix
Measured according to standard
None
Comment on measurement
Crucible: Al. pan, closed. Purge gas: Nitrogen with 20 ml/min. 3 Heating & Cooling cycles between 105 and 160 °C with 10 K/min. Heat calibration performed.
Reference
Heating rate
10 K/min
Cooling rate
10 K/min
Sample mass
8.3 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
236.27 kJ/kg
2.84 kJ/kg
214.4 kJ/kg
0.2 kJ/kg
Integration lower limit
124.27 °C
139.32 °C
Integration upper limit
153.11 °C
111.35 °C
Onset temperature
132.07 °C
0.07 K
136.97 °C
0.13 K
Endset temperature
146.87 °C
0.24 K
117.8 °C
0.6 K
Suberic acid: Heating/cooling enthalpy measurement 1
Suberic acid: Heating/cooling enthalpy measurement 2
Suberic acid: Heating/cooling enthalpy measurement 3
Reference measurement

Suberic acid: Heating/cooling enthalpy measurement 1

Suberic acid: Heating/cooling enthalpy measurement 1

Suberic acid: Heating/cooling enthalpy measurement 2

Suberic acid: Heating/cooling enthalpy measurement 2

Suberic acid: Heating/cooling enthalpy measurement 3

Suberic acid: Heating/cooling enthalpy measurement 3