enthalpy sample 2

Measured by
Austrian Institute of Technology
Measured with NETZSCH DSC 204F1 Phoenix
Measured according to standard
Task 4229 PCM DSC procedure
Comment on measurement
Crucible: Al. pan, closed. Purge gas: Nitrogen. Number of heating & cooling cycles: 3.
Reference
Heating rate
0.25 K/min
Cooling rate
0.25 K/min
Sample mass
11.47 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
209.71 kJ/kg
1.82 kJ/kg
207.49 kJ/kg
0.53 kJ/kg
Integration lower limit
25.33 °C
26.23 °C
Integration upper limit
28.9 °C
24.17 °C
Onset temperature
27.1 °C
0 K
26.07 °C
0.07 K
Endset temperature
28.67 °C
0.07 K
24.7 °C
0.12 K