enthalpy sample 2

Measured by
Austrian Institute of Technology
Measured with NETZSCH DSC 204 F1 Phoenix
Measured according to standard
None
Comment on measurement
Crucible: Al. pan, closed. Purge gas: Nitrogen with 20 ml/min. 3 Heating & Cooling cycles between 10 and 85 °C with 10 K/min. Heat calibration performed.
Reference
Heating rate
10 K/min
Cooling rate
10 K/min
Sample mass
10.46 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
224.77 kJ/kg
0.07 kJ/kg
224.83 kJ/kg
0.18 kJ/kg
Integration lower limit
40.6 °C
58.9 °C
Integration upper limit
79.6 °C
32.8 °C
Onset temperature
59.3 °C
0.07 K
57.7 °C
0.13 K
Endset temperature