enthalpy sample 1

Measured by
Austrian Institute of Technology
Measured with NETZSCH DSC 204 F1 Phoenix
Measured according to standard
None
Comment on measurement
Crucible: Al. pan, closed. Purge gas: Nitrogen with 20 ml/min. 3 Heating & Cooling cycles between 10 and 85 °C with 10 K/min. Heat calibration performed.
Reference
Heating rate
10 K/min
Cooling rate
10 K/min
Sample mass
9.27 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
227 kJ/kg
0.12 kJ/kg
227.27 kJ/kg
0.24 kJ/kg
Integration lower limit
39.6 °C
59.7 °C
Integration upper limit
77.8 °C
32.6 °C
Onset temperature
59.2 °C
0.07 K
57.9 °C
0 K
Endset temperature
RT60HC: Heating/cooling enthalpy measurement 1
RT60HC: Heating/cooling enthalpy measurement 2
RT60HC: Heating/cooling enthalpy measurement 3

RT60HC: Heating/cooling enthalpy measurement 1

RT60HC: Heating/cooling enthalpy measurement 1

RT60HC: Heating/cooling enthalpy measurement 2

RT60HC: Heating/cooling enthalpy measurement 2

RT60HC: Heating/cooling enthalpy measurement 3

RT60HC: Heating/cooling enthalpy measurement 3