enthalpy sample 2

Measured by
Test
Measured with Test
Measured according to standard
Comment on measurement
Reference
Heating rate
0.5 K/min
Cooling rate
0.5 K/min
Sample mass
10.53 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
135.2 kJ/kg
0.1 kJ/kg
114.6 kJ/kg
1.3 kJ/kg
Integration lower limit
25 °C
40 °C
Integration upper limit
0 °C
5 °C
Onset temperature
33.3 °C
0 K
35.2 °C
0 K
Endset temperature
2.3 °C
1.6 K
1.9 °C
1.6 K
Calciumbromid Hexahydrate: Heating/cooling measurement 1
Calciumbromid Hexahydrate: Heating/cooling measurement 2
Calciumbromid Hexahydrate: Heating/cooling measurement 3

Calciumbromid Hexahydrate: Heating/cooling measurement 1

Calciumbromid Hexahydrate: Heating/cooling measurement 1

Calciumbromid Hexahydrate: Heating/cooling measurement 2

Calciumbromid Hexahydrate: Heating/cooling measurement 2

Calciumbromid Hexahydrate: Heating/cooling measurement 3

Calciumbromid Hexahydrate: Heating/cooling measurement 3
Gefördert durch das Bundesministerium für Wirtschaft und Klimaschutz