You are here: Home / PCM / Octadecan Parafol 18-97 / Enthalpy (T)

Enthalpy (T)

Measurement details

Measured with TA Q200 (Heatflux)
By: Fraunhofer ISE
Additional Comments Sample 1
  • Heating rate0.5 [K/min]
  • Cooling rate0.5 [K/min]
  • Sample mass10.49 [mg]
  • Heat of fusion232.4 [kJ/kg] - deviation0.1 [kJ/kg]
    • Integration range, lower limit20.0 [°C]
    • Integration range, upper limit34.0 [°C]
    • Onset temperature27.34 [°C] - deviation0.02 [°C]
    • Offset temperature29.75 [°C] - deviation0.06 [°C]
  • Crystallization enthalpy233.8 [kJ/kg] - deviation0.1 [kJ/kg]
    • Integration range, lower limit20.0 [°C]
    • Integration range, upper limit27.0 [°C]
    • Onset26.74 [°C] - deviation0.35 [°C]
    • Offset26.39 [°C] - deviation0.96 [°C]
Enthalpy (T)

Set 1/ db-materials-heating_cooling_measurements

Heating - sample1_melt_cycle1_0K5.dat

Cooling - sample1_cool_cycle1_0K5.dat

Set 2/ db-materials-heating_cooling_measurements-1

Heating - sample1_melt_cycle2_0K5.dat

Cooling - sample1_cool_cycle2_0K5.dat

Set 3/ db-materials-heating_cooling_measurements-2

Heating - sample1_melt_cycle3_0K5.dat

Cooling - sample1_cool_cycle3_0K5.dat